Does ultrasonic bath cleaning damage laboratory volumetric glassware calibration?How to get meniscus down to the calibration mark with a volumetric pipette
Can a Horncaller control a Druid who is using Wild Shape?
Animation advice please
What sort of mathematical problems are there in AI that people are working on?
Is this one of the engines from the 9/11 aircraft?
Why is there no havdallah when going from Yom Tov into Shabbat?
Cascading Repair Costs following Blown Head Gasket on a 2004 Subaru Outback
Using “sparkling” as a diminutive of “spark” in a poem
MH370 blackbox - is it still possible to retrieve data from it?
Are there any vegetarian astronauts?
Employer wants to use my work email account after I quit, is this legal under German law? Is this a GDPR waiver?
Peace Arch without exiting USA
Do flight schools typically have dress codes or expectations?
What are the benefits of using the X Card safety tool in comparison to plain communication?
In the Marvel universe, can a human have a baby with any non-human?
Why is Madam Hooch not a professor?
How to get cool night-vision without lame drawbacks?
Analog is Obtuse!
Links to webpages in books
What happens when I sacrifice a creature when my Teysa Karlov is on the battlefield?
Can the negators "jamais, rien, personne, plus, ni, aucun" be used in a single sentence?
How to split an equation over two lines?
Why is C++ initial allocation so much larger than C's?
How well known and how commonly used was Huffman coding in 1979?
C-152 carb heat on before landing in hot weather?
Does ultrasonic bath cleaning damage laboratory volumetric glassware calibration?
How to get meniscus down to the calibration mark with a volumetric pipette
.everyoneloves__top-leaderboard:empty,.everyoneloves__mid-leaderboard:empty,.everyoneloves__bot-mid-leaderboard:empty margin-bottom:0;
$begingroup$
As an analytical chemist, I'm always ensuring my glassware is thoroughly clean before I start an analysis. However, my supervisor always states that using ultrasonic bath to clean volumetric glassware damages its calibration, rendering it imprecise for analytical usage. Does that hold true, or is it okay to use an ultrasonic cleaner?
experimental-chemistry analytical-chemistry
New contributor
Roman is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.
$endgroup$
add a comment |
$begingroup$
As an analytical chemist, I'm always ensuring my glassware is thoroughly clean before I start an analysis. However, my supervisor always states that using ultrasonic bath to clean volumetric glassware damages its calibration, rendering it imprecise for analytical usage. Does that hold true, or is it okay to use an ultrasonic cleaner?
experimental-chemistry analytical-chemistry
New contributor
Roman is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.
$endgroup$
2
$begingroup$
Unless it fractured the glassware I don’t see the issue.
$endgroup$
– Jon Custer
9 hours ago
$begingroup$
I sometimes sonicate volumetrics to help dissolution for a short period. However, I am actually curious about the following test, which I vaguely recall (and therefore could be wrong). If we make up the volume exactly to mark, and then sonicate, what happens to meniscus? It goes down slightly below the mark temporarily. This could be from local heating of the glass. Glass and solutions do heat up during sonication.
$endgroup$
– M. Farooq
2 hours ago
add a comment |
$begingroup$
As an analytical chemist, I'm always ensuring my glassware is thoroughly clean before I start an analysis. However, my supervisor always states that using ultrasonic bath to clean volumetric glassware damages its calibration, rendering it imprecise for analytical usage. Does that hold true, or is it okay to use an ultrasonic cleaner?
experimental-chemistry analytical-chemistry
New contributor
Roman is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.
$endgroup$
As an analytical chemist, I'm always ensuring my glassware is thoroughly clean before I start an analysis. However, my supervisor always states that using ultrasonic bath to clean volumetric glassware damages its calibration, rendering it imprecise for analytical usage. Does that hold true, or is it okay to use an ultrasonic cleaner?
experimental-chemistry analytical-chemistry
experimental-chemistry analytical-chemistry
New contributor
Roman is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.
New contributor
Roman is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.
New contributor
Roman is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.
asked 9 hours ago
RomanRoman
311 bronze badge
311 bronze badge
New contributor
Roman is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.
New contributor
Roman is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.
2
$begingroup$
Unless it fractured the glassware I don’t see the issue.
$endgroup$
– Jon Custer
9 hours ago
$begingroup$
I sometimes sonicate volumetrics to help dissolution for a short period. However, I am actually curious about the following test, which I vaguely recall (and therefore could be wrong). If we make up the volume exactly to mark, and then sonicate, what happens to meniscus? It goes down slightly below the mark temporarily. This could be from local heating of the glass. Glass and solutions do heat up during sonication.
$endgroup$
– M. Farooq
2 hours ago
add a comment |
2
$begingroup$
Unless it fractured the glassware I don’t see the issue.
$endgroup$
– Jon Custer
9 hours ago
$begingroup$
I sometimes sonicate volumetrics to help dissolution for a short period. However, I am actually curious about the following test, which I vaguely recall (and therefore could be wrong). If we make up the volume exactly to mark, and then sonicate, what happens to meniscus? It goes down slightly below the mark temporarily. This could be from local heating of the glass. Glass and solutions do heat up during sonication.
$endgroup$
– M. Farooq
2 hours ago
2
2
$begingroup$
Unless it fractured the glassware I don’t see the issue.
$endgroup$
– Jon Custer
9 hours ago
$begingroup$
Unless it fractured the glassware I don’t see the issue.
$endgroup$
– Jon Custer
9 hours ago
$begingroup$
I sometimes sonicate volumetrics to help dissolution for a short period. However, I am actually curious about the following test, which I vaguely recall (and therefore could be wrong). If we make up the volume exactly to mark, and then sonicate, what happens to meniscus? It goes down slightly below the mark temporarily. This could be from local heating of the glass. Glass and solutions do heat up during sonication.
$endgroup$
– M. Farooq
2 hours ago
$begingroup$
I sometimes sonicate volumetrics to help dissolution for a short period. However, I am actually curious about the following test, which I vaguely recall (and therefore could be wrong). If we make up the volume exactly to mark, and then sonicate, what happens to meniscus? It goes down slightly below the mark temporarily. This could be from local heating of the glass. Glass and solutions do heat up during sonication.
$endgroup$
– M. Farooq
2 hours ago
add a comment |
2 Answers
2
active
oldest
votes
$begingroup$
According to technical information for volumetric measurement provided by Brand, it is acceptable to use an ultrasonic bath.
Both glass and plastic labware may be cleaned in an ultrasonic bath. However, direct contact with the sonic membranes must be avoided.
Nevertheless,
For gentle treatment of labware, clean immediately after use – at low temperatures, with brief soaking times, and at low alkalinity. Glass volumetric instruments should not be exposed to prolonged immersion times in alkaline media above 70 °C, as such treatment causes volume changes through glass corrosion, and destruction of graduations.
$endgroup$
add a comment |
$begingroup$
If your supervisor is unconvinced by Brand's guidance on this (as supplied by Loong in his answer), you could always test the effect of ultrasonic cleaning directly:
Take, say, six volumetric flasks, and weigh the amount of water each holds when filled to the line. Then subject three to several cycles of ultrasonic cleaning (the other three can be left to sit in the ultrasonic cleaning solution, but without turning the machine on), dry all six, and repeat the weighing measurement. Determine if the before-and-after difference for the ultrasonically cleaned flasks is significantly different from that seen in the control flasks.
While the control flasks do control for temperature differences between the before-and-after measurements, it would be cleaner if you could do the before-and-after measurements at the same temperature. That way the only difference you see should be random experimental error plus any systematic differences due to cleaning.
$endgroup$
add a comment |
Your Answer
StackExchange.ready(function()
var channelOptions =
tags: "".split(" "),
id: "431"
;
initTagRenderer("".split(" "), "".split(" "), channelOptions);
StackExchange.using("externalEditor", function()
// Have to fire editor after snippets, if snippets enabled
if (StackExchange.settings.snippets.snippetsEnabled)
StackExchange.using("snippets", function()
createEditor();
);
else
createEditor();
);
function createEditor()
StackExchange.prepareEditor(
heartbeatType: 'answer',
autoActivateHeartbeat: false,
convertImagesToLinks: false,
noModals: true,
showLowRepImageUploadWarning: true,
reputationToPostImages: null,
bindNavPrevention: true,
postfix: "",
imageUploader:
brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
allowUrls: true
,
onDemand: true,
discardSelector: ".discard-answer"
,immediatelyShowMarkdownHelp:true
);
);
Roman is a new contributor. Be nice, and check out our Code of Conduct.
Sign up or log in
StackExchange.ready(function ()
StackExchange.helpers.onClickDraftSave('#login-link');
);
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
StackExchange.ready(
function ()
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fchemistry.stackexchange.com%2fquestions%2f117175%2fdoes-ultrasonic-bath-cleaning-damage-laboratory-volumetric-glassware-calibration%23new-answer', 'question_page');
);
Post as a guest
Required, but never shown
2 Answers
2
active
oldest
votes
2 Answers
2
active
oldest
votes
active
oldest
votes
active
oldest
votes
$begingroup$
According to technical information for volumetric measurement provided by Brand, it is acceptable to use an ultrasonic bath.
Both glass and plastic labware may be cleaned in an ultrasonic bath. However, direct contact with the sonic membranes must be avoided.
Nevertheless,
For gentle treatment of labware, clean immediately after use – at low temperatures, with brief soaking times, and at low alkalinity. Glass volumetric instruments should not be exposed to prolonged immersion times in alkaline media above 70 °C, as such treatment causes volume changes through glass corrosion, and destruction of graduations.
$endgroup$
add a comment |
$begingroup$
According to technical information for volumetric measurement provided by Brand, it is acceptable to use an ultrasonic bath.
Both glass and plastic labware may be cleaned in an ultrasonic bath. However, direct contact with the sonic membranes must be avoided.
Nevertheless,
For gentle treatment of labware, clean immediately after use – at low temperatures, with brief soaking times, and at low alkalinity. Glass volumetric instruments should not be exposed to prolonged immersion times in alkaline media above 70 °C, as such treatment causes volume changes through glass corrosion, and destruction of graduations.
$endgroup$
add a comment |
$begingroup$
According to technical information for volumetric measurement provided by Brand, it is acceptable to use an ultrasonic bath.
Both glass and plastic labware may be cleaned in an ultrasonic bath. However, direct contact with the sonic membranes must be avoided.
Nevertheless,
For gentle treatment of labware, clean immediately after use – at low temperatures, with brief soaking times, and at low alkalinity. Glass volumetric instruments should not be exposed to prolonged immersion times in alkaline media above 70 °C, as such treatment causes volume changes through glass corrosion, and destruction of graduations.
$endgroup$
According to technical information for volumetric measurement provided by Brand, it is acceptable to use an ultrasonic bath.
Both glass and plastic labware may be cleaned in an ultrasonic bath. However, direct contact with the sonic membranes must be avoided.
Nevertheless,
For gentle treatment of labware, clean immediately after use – at low temperatures, with brief soaking times, and at low alkalinity. Glass volumetric instruments should not be exposed to prolonged immersion times in alkaline media above 70 °C, as such treatment causes volume changes through glass corrosion, and destruction of graduations.
answered 9 hours ago
Loong♦Loong
35.3k8 gold badges88 silver badges190 bronze badges
35.3k8 gold badges88 silver badges190 bronze badges
add a comment |
add a comment |
$begingroup$
If your supervisor is unconvinced by Brand's guidance on this (as supplied by Loong in his answer), you could always test the effect of ultrasonic cleaning directly:
Take, say, six volumetric flasks, and weigh the amount of water each holds when filled to the line. Then subject three to several cycles of ultrasonic cleaning (the other three can be left to sit in the ultrasonic cleaning solution, but without turning the machine on), dry all six, and repeat the weighing measurement. Determine if the before-and-after difference for the ultrasonically cleaned flasks is significantly different from that seen in the control flasks.
While the control flasks do control for temperature differences between the before-and-after measurements, it would be cleaner if you could do the before-and-after measurements at the same temperature. That way the only difference you see should be random experimental error plus any systematic differences due to cleaning.
$endgroup$
add a comment |
$begingroup$
If your supervisor is unconvinced by Brand's guidance on this (as supplied by Loong in his answer), you could always test the effect of ultrasonic cleaning directly:
Take, say, six volumetric flasks, and weigh the amount of water each holds when filled to the line. Then subject three to several cycles of ultrasonic cleaning (the other three can be left to sit in the ultrasonic cleaning solution, but without turning the machine on), dry all six, and repeat the weighing measurement. Determine if the before-and-after difference for the ultrasonically cleaned flasks is significantly different from that seen in the control flasks.
While the control flasks do control for temperature differences between the before-and-after measurements, it would be cleaner if you could do the before-and-after measurements at the same temperature. That way the only difference you see should be random experimental error plus any systematic differences due to cleaning.
$endgroup$
add a comment |
$begingroup$
If your supervisor is unconvinced by Brand's guidance on this (as supplied by Loong in his answer), you could always test the effect of ultrasonic cleaning directly:
Take, say, six volumetric flasks, and weigh the amount of water each holds when filled to the line. Then subject three to several cycles of ultrasonic cleaning (the other three can be left to sit in the ultrasonic cleaning solution, but without turning the machine on), dry all six, and repeat the weighing measurement. Determine if the before-and-after difference for the ultrasonically cleaned flasks is significantly different from that seen in the control flasks.
While the control flasks do control for temperature differences between the before-and-after measurements, it would be cleaner if you could do the before-and-after measurements at the same temperature. That way the only difference you see should be random experimental error plus any systematic differences due to cleaning.
$endgroup$
If your supervisor is unconvinced by Brand's guidance on this (as supplied by Loong in his answer), you could always test the effect of ultrasonic cleaning directly:
Take, say, six volumetric flasks, and weigh the amount of water each holds when filled to the line. Then subject three to several cycles of ultrasonic cleaning (the other three can be left to sit in the ultrasonic cleaning solution, but without turning the machine on), dry all six, and repeat the weighing measurement. Determine if the before-and-after difference for the ultrasonically cleaned flasks is significantly different from that seen in the control flasks.
While the control flasks do control for temperature differences between the before-and-after measurements, it would be cleaner if you could do the before-and-after measurements at the same temperature. That way the only difference you see should be random experimental error plus any systematic differences due to cleaning.
edited 4 hours ago
answered 4 hours ago
theoristtheorist
33310 bronze badges
33310 bronze badges
add a comment |
add a comment |
Roman is a new contributor. Be nice, and check out our Code of Conduct.
Roman is a new contributor. Be nice, and check out our Code of Conduct.
Roman is a new contributor. Be nice, and check out our Code of Conduct.
Roman is a new contributor. Be nice, and check out our Code of Conduct.
Thanks for contributing an answer to Chemistry Stack Exchange!
- Please be sure to answer the question. Provide details and share your research!
But avoid …
- Asking for help, clarification, or responding to other answers.
- Making statements based on opinion; back them up with references or personal experience.
Use MathJax to format equations. MathJax reference.
To learn more, see our tips on writing great answers.
Sign up or log in
StackExchange.ready(function ()
StackExchange.helpers.onClickDraftSave('#login-link');
);
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
StackExchange.ready(
function ()
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fchemistry.stackexchange.com%2fquestions%2f117175%2fdoes-ultrasonic-bath-cleaning-damage-laboratory-volumetric-glassware-calibration%23new-answer', 'question_page');
);
Post as a guest
Required, but never shown
Sign up or log in
StackExchange.ready(function ()
StackExchange.helpers.onClickDraftSave('#login-link');
);
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
Sign up or log in
StackExchange.ready(function ()
StackExchange.helpers.onClickDraftSave('#login-link');
);
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
Sign up or log in
StackExchange.ready(function ()
StackExchange.helpers.onClickDraftSave('#login-link');
);
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
2
$begingroup$
Unless it fractured the glassware I don’t see the issue.
$endgroup$
– Jon Custer
9 hours ago
$begingroup$
I sometimes sonicate volumetrics to help dissolution for a short period. However, I am actually curious about the following test, which I vaguely recall (and therefore could be wrong). If we make up the volume exactly to mark, and then sonicate, what happens to meniscus? It goes down slightly below the mark temporarily. This could be from local heating of the glass. Glass and solutions do heat up during sonication.
$endgroup$
– M. Farooq
2 hours ago